© 2011 Eaton. All rights reserved. Common Denmark seminar 2.Februar 2015 Bozidar Dedic ET & IT Channel Manager
© 2011 Eaton. All rights reserved. 1.Kort intro til Eaton 2.Generelt om UPS teknologier 3.Input til en fornuftigt UPS løsning 4.”Grøn IT” 5.Virtualiseret UPS Agenda : UPS I øjenhøjde
© 2011 Eaton. All rights reserved. Eaton Corporation Eaton i 2013 tal Nettooms. $ 22 mia. Ca ansatte Kunder i mere end 175 lande Eaton Corporation Grundlagt i 1911 af J.O. Eaton Hovedkvarter i Cleveland, Ohio USA Bestyrelsesformand & CEO Alexander M. Cutler Vores vision: ”To be the most admired company in our markets”
© 2011 Eaton. All rights reserved. A Strong Presence In EMEA Main 3 phase factory in Espoo (Finland). ePDU manufacturing in Marroco 4 R&D centers in Europe Distributed Power Solutions - Montbonnot (France) Critical Power Solutions - Espoo (Finland) Telecom Solutions - Le Lieu (Switzerland) Telecom Solutions - Bognor Regis (UK) Other R&D centers worldwide, including: in Raleigh NC (US) Suzhou/Changzhou & Shenzhen (China)
© 2011 Eaton. All rights reserved. De grundlæggende UPS topologier Lad os starte fra det helt basale.
© 2011 Eaton. All rights reserved. Buck/Boost Converter On-Line OFF-Line (Backups) Line-Interactive
© 2011 Eaton. All rights reserved. De tre UPS teknologier…….
© 2011 Eaton. All rights reserved. UPS beskyttelse af IT 230V Server o.a beskyttet udstyr On-Line UPS med statisk Bypass + ekstern Service Bypass Ekstern Service Bypass betyder udvidelser og service uden nedlukning af det beskyttede udstyr (findes til alle Powerware og Pulsar Serie-9 UPS løsninger)
© 2011 Eaton. All rights reserved. 1.Powerfactor/Cos. Phi 2.Batterier. 3.Effektivitet (kommer vi tilbage til ) 3 vigtige parametre ved UPSer.
© 2011 Eaton. All rights reserved. Eaton VA = Maks output 2700W VS XXX UPS 3000VA = Maks output 2100W Powerfactor/Cos. Phi
© 2011 Eaton. All rights reserved. Er en pæn del af UPSen pris Er sårbare overfor temperaturer over 25 grader Skal vedligeholdes/skiftes. Eaton ”kører” ABM teknologi. Batterier
© 2011 Eaton. All rights reserved. UPS Strategier ”Serverrum”
© 2011 Eaton. All rights reserved. UPS Strategier ”Serverrum”
© 2011 Eaton. All rights reserved. Dyr løsning Mange fejlmuligheder Normalt ingen redundans Megen vedligehold Dårligt overblik ”Mange” UPSer i rummet
© 2011 Eaton. All rights reserved. -Dyr: 2 x kapacitet er nødvendig -Ekstra vedligehold - Nedlukning kan være et problem 2 UPSer til samme server
© 2011 Eaton. All rights reserved. 1 forsyning på UPS og 1 i bystrøm UPS Forsynet By strøm - Ingen besparelse på UPS kapacitet - Ufiltreret bystrøm direkte ind i udstyr - Høje krav til ”kontrol” med kapacitet
© 2011 Eaton. All rights reserved. UPS EL- Tavle 9390 UPS 40kVA (36000W) m/10års batterier Forsyning 1. Forsyning 2. Bypass fors. 16A forsyning Bypass 32A forsyning PDU forsyning 1100kg Ved at placere UPS el-tave i Server-rum Minimeres kabeltræk til Infrastrukturen 1888 mm 165cm
© 2011 Eaton. All rights reserved. Energi kontrol Energi besparelser. Grøn IT :
© 2011 Eaton. All rights reserved. - Montorering Grøn IT :Energi kontrol
© 2011 Eaton. All rights reserved. IPM overvågning Use your own background to display and monitor your Eaton devices
© 2011 Eaton. All rights reserved. IPM ePDU IPM supervise & manage devices and protect his own server
© 2011 Eaton. All rights reserved. Intelligent Power® Monitoring Manage your power consumption Control your operating costs by monitoring and tracking consumption from rack to branch, right down to the individual server Easily identify physical branch sections and related breakers through Colour-coded sections Server or branch
© 2011 Eaton. All rights reserved. Intelligent Power® Monitoring Manage your power consumption Accurate measurements enables tracking, trending and analysis Total understanding of your rack power distribution
© 2011 Eaton. All rights reserved. Intelligent Power® Control Complete control and remote switching Control your power distribution and consumption Build knowledge base of what is going on Switch, sequence outlets and outlet groups as well as individually monitor – you have complete control
© 2011 Eaton. All rights reserved. Power Distrubution Unit ePDU Managed
© 2011 Eaton. All rights reserved. Installerede UPSer har et REELT tab på mellem 10-20% af belastningen. Grøn IT :Energi besparelser
© 2011 Eaton. All rights reserved. Ved 10% tab og energi omkostning på 2 kr kw/t W IT koster ca ,- i UPS forbrug årligt W IT koster ca ,- i UPS forbrug årligt W IT koster ca ,- i UPS forbrug årligt Læg dertil omkostningen til at køle varmetabet. UPS omkostning:
© 2011 Eaton. All rights reserved. Eaton Teknologi : ESS 99% effektivitet Grøn IT :Energi besparelser
© 2011 Eaton. All rights reserved. Online UPS 1: Normal drift
© 2011 Eaton. All rights reserved. Online UPS 2: ESS/High-Effiency mode
© 2011 Eaton. All rights reserved. En W koster ca ,- Energi besparelsen kan være ca årligt Læg dertil besparelsen på køl ESS besparelse:
© 2011 Eaton. All rights reserved. ”Skyen” som back up site. ”Virtualiseret UPS”
© 2011 Eaton. All rights reserved. Protection summary UPS on battery IPM sends shutdown command to ESXi ESXi graceful shutdown all VM’s ESXi shutdown UPS on battery IPM sends shutdown command to ESXi or vMotion via the vCenter ESXi graceful shutdown all VM’s ESXi shutdown
© 2011 Eaton. All rights reserved. Eaton solution’s for VMware environment
© 2011 Eaton. All rights reserved. Intelligent Power Manager is fully integrated into vCenter and XenCenter ! IPM [plug-in]
© 2011 Eaton. All rights reserved. Vi afholder et uddybende software seminar i maj. Nysgerrig omkring vores software ?
© 2011 Eaton. All rights reserved. Spørgsmål ?