IBM POWER BladeServer Teknisk Goodies Dag

Slides:



Advertisements
Lignende præsentationer
IT Projekt Portefølje Management: styringsmæssige og koordineringsmæssige problemer i en offentlig organisation.
Advertisements

Next Generation Operations Management AutoNOC 2. AutoNOC 2 Business fordele.
Indsæt nyt billede: Format: B 254 x 190,5 mm Efter indsættelse, højreklik på billedet og placér det bagerst. Delete det gamle foto Legal aid in Denmark.
Torben Andersen Teknisk specialist. Praktisk informatio  Parkering – suk suk  Frokost  Handsout.
2.-generationsintranet på KU Internet, intranet, ekstranet eller "mit net"? Claus Qvistgaard It-strategichef
Dansk Landbrugsrådgivning Landscentret Continuous Integration DCFServices.
IT og økonomi Lektion: N: Netværk.
KA2000 Projektet Konsolidering og kontorautomation i et projekt Per Schou Christensen - IT-arkitekt Post Danmark
Backup/Storage Søren Helmer Jensen.
edgemo summit Session: ”Skomagerbackup”
Kristian F. Thomsen infrastructure specialist i edgemo Claus Egeberg-Gjelstrup infrastructure specialist i edgemo
Grøn Plan fra Novo Kilde Børsen 27 feb Novos Klimastrategi.
For at ændre ”Enhedens navn” og ”Sted og dato”: Klik i menulinjen, vælg ”Indsæt” > ”Sidehoved / Sidefod”. Indføj ”Sted og dato” i feltet for dato og ”Enhedens.
Change Triangle – “Learning by Playing” as a tool for change - example from the Altiplano in Bolivia.
OIOXML Anvendelse i Virk.dk
Serverkonsolidering Peter Colsted Direktør Enterprise & Partner Group Microsoft Danmark.
Claus Egeberg-Gjelstrup infrastructure specialist i edgemo
Præsentation af Aalborg Universitet 1 af 24 UWT seminar 2010 Jesper Ellerbæk Nielsen ”Combining C-band and X-band weather radars for accurate precipitation.
1 Samarbejdsmodeller i byggeprocessen Fredag d. 24. august Aalborg Universitet Livslang Uddannelse 2001.
Indhold Opsummering Opsummering  Standardisering, sikkerhed, forbedret administration & vedligehold, øget produktivitetsmuligheder = omkostningsbesparelser.
EFE1 DC-AC invertere, drives Mohahan Kap J.Nybo
CORBA/e CORBA and Embedded Systems OOMI 27. November 2006.
Personal Leadership Bachelor of Leisure Management.
Forretning og Ledelse – Lektion 7
Velkommen Vi starter kl Hvis du vil vide mere om Microsoft BI... Spørg en af os ved standen i foyéen Se kursustilbud og data sheet i din deltagermappe.
Kjeld Svidt  Institut for Byggeri og Anlæg  Aalborg Universitet IT i Byggeriet Semester 6, kursusgang Databaser (1) Kjeld Svidt
Lene Sandholdt & Johan Kulmbach
3. time Her beskæftiger vi os med John F. Sowas forklaring af erfaringsviden. John F. Sowa.
DB analyse og modellering Jesper Tørresø DAB1 F Februar 2008.
Sted og dato (Indsæt --> Diasnummer) Dias 1 Navn på enhed (Indsæt --> Diasnummer) Davenport et al. (2000) Vs Adelman et. Al (2002) Possible states for.
OPERATIONEL ANALYSE AF WEBADFÆRD OAW – LEKTIONSGANG 4.
Project Management Managing The Progress of Projects.
2 minutter om tid (og rum) Lisbeth Klastrup 7. kursusgang 23. oktober.
Overskrift her Navn på oplægsholder Navn på KU- enhed For at ændre ”Enhedens navn” og ”Sted og dato”: Klik i menulinjen, vælg ”Indsæt” > ”Sidehoved / Sidefod”.
 Jens Bennedsen 2002Objektorienteret systemudvikling GRASP mønstre Basale ansvarsplaceringsregler.
ANALYSE AF WEBADFÆRD - OAW OAW – LEKTIONSGANG 4. ANALYSE AF WEBADFÆRD - OAW SUMMARY, LECTURE 3 (Extended) Common Log File Format Host, Ident, Authuser,
NFIT- backupgruppe – december 2006 A A R H U S U N I V E R S I T E T Naturvidenskabeligt Fakultet NFIT- backupsystem.
Microsoft Storage Spaces Niels Vejrup Pedersen, edgemo a/s Infrastructure Specialist.
SAP Best Practices Færdigpakket branchespecifik og brancheovergribende knowhow Tilgængelighed for SAP-kunder og SAP-partnere.
DOMS IT-stormøde 16 november 2009 Kåre Fiedler Christiansen.
Mikkel deMib Svendsen Duplicate Content & Multiple Site Issue Mikkel deMib Svendsen
EERA Design Tool for Offshore wind farm Cluster (DTOC) Peter Hauge Madsen. Director Charlotte Hasager. Senior scientist DTU Wind Energy Support by EERA.
Omsætning af en model til en RDB Jesper Tørresø DAB1 F Marts 2008.
1 (c) W. J. Dally Digital Design: A Systems Approach Lecture 12: Timing.
GS – den 3. februar Dagens mix… IBEV – april. Common – CEC: Common – CEC: Adwards. Adwards. Krakow – juni. Krakow – juni. GS-web – version 4.3. (Version.
Insert picture: Click the icon and insert a picture from your folders. Right-click the picture and ”Send to back”. Change logo Right-click logo and select.
CEAC Hvad er det ? Hvad kan vi få ud af det ? v/ Dan Foldager.
© 2011 Eaton. All rights reserved. Common Denmark seminar 2.Februar 2015 Bozidar Dedic ET & IT Channel Manager.
Underoverskrift 17 pkt bold hvid Maks. 2 linjer med respekt for evt logo Indsæt billede >Klik på billedikonet og indsæt billede Efter indsættelse >Højreklik.
Ledende oversygeplejerske Arne Brehm Høj Afdeling for Operation og Anæstesiologi Sydvestjysk Sygehus.
1 Finn Jensen CEO Password for iSeries COMMON præsentation 5.feb
Opdatér dato Vælg >Indsæt >Sidehoved / Sidefod Skriv Måned og År i feltet for dato Vis hjælpelinjer som er en hjælp ved placering af billeder: 1.Højreklik.
Drug/Device Combination Products IFF erfagruppemøde
SCALE-UP DENMARK Tue David Bak Direktør, Innovation & Vækst, Region Sjælland & Formand for Scale-Up Denmark Thank you to the Ambassador, Mrs Louise Jespersen.
Movex Java Allan Randa IT Arkitekt Intentia Danmark A/S
Dansk HL7 CDA profil til deling af aftaler Data i en aftale
DB analyse og modellering
Sense My City Develco A/S.
Software Testing Software testing.
MaaS i Europe Rasmus Lindholm.
Alternative fuels for HDV - Perspectives from the Danish Energy Agency
Object Storage - NetApp Storage Grid
Hvordan kommer min virksomhed videre?
Hot work Planning: 01.Februar 2008 Outdoor: 01.Februar 2008
Inside UEFI/BIOS Ronnie Jakobsen
F-Secure Teknik – derfor
Benchmark Føroya Gjaldstova
”Show me your tools” session: Slurm kø-system tools
Smart Data Tool (SDT) In Sales
Hærens ESRI Enterprise Transformation
Præsentationens transcript:

IBM POWER BladeServer Teknisk Goodies Dag Nyheder (IBM Bladeserver & IBM BladeCenter) POWER Blade kan afvikle IBM i (OS/400) Kan M3 afvikles på POWER Blade med IBM i? Er der ting som man skal være opmærksom på med IBM POWER Blade? Kan jeg lave helt de samme ting på POWER Blade som jeg gør i dag på en traditionel POWER server (AS/400) ? Danni Stjernegaard Salgsdirektør dast@atea.dk Tlf.: 2270 6626 1

Hvad er bladeserver-løsning ? Layer 2 switches Storage fibre switches SAN Layer 4-7 switches Public Internet/ intranet clients Routers (L3 switches) Firewalls File servers Web Security gateway IBM WebSphere® Application Server software Network

Alt i en box Public Internet/ intranet clients Routers Firewalls SAN 3

Alt i en box 4 Multiple server management tools reduced to one Storage area network (SAN) cables removed Local area network (LAN) cables removed Multiple external switches integrated inside the chassis Keyboard, video, mouse (KVM) costs eliminated Power distribution unit (PDU) costs drastically reduced Energy, heat and floor space conserved Public Internet/ intranet clients Routers Firewalls SAN 4

Nyheder System i™ System p™ i515 i525 i550 i570 i595 BladeCenter® JS12/JS22 Power 520 Power 550 Power 560 Power 570 Power 595 System p™ BladeCenter JS21/JS22 p5-510/Q p5-505/Q p520 p550 p5-560Q p-570 p5-595

BladeCenter Chassis A common set of blades i supports BladeCenter S that integrates blades and storage in the chassis and BladeCenter H for larger implementations IBM BladeCenter T Ruggedized IBM BladeCenter E Best energy efficiency, best density IBM BladeCenter H High performance IBM BladeCenter S Distributed, small office, easy to configure IBM BladeCenter HT Ruggedized, high performance A common set of blades A common set of industry-standard switches and I/O fabrics A common management infrastructure

BladeCenter Chassis i supports BladeCenter S for small and distributed deployments and BladeCenter H for larger deployments Chassis BCH BCS # of Blades 14 6 # of Disk Drives 0-12 (SAS) Disk Capacity (Max) 5.4 TB Power 220 110 or 220 Blades x86 and POWER Redundant Power and Cooling Yes Management Modules 1-2 1 Blades for i JS22 and JS12 JS12 and JS22

Meet the BladeCenter H

Meet the IBM BladeCenter S 12 Disk Drives 7U 6 Blades CD-RW / DVD-ROM

BladeCenter Blades A common set of blades IBM offers x86 and POWER processor-based blades to support a wide variety of operating system and performance requirements HS12 General-purpose enterprise HS21 XM Extended-memory QS21 High performance LS41 Scalable, enterprise performance JS12 High-performance, virtualization HS21 General-purpose enterprise LS21 High performance HC10 Workstation JS22 Scalable performance, virtualization A common set of blades A common set of industry-standard switches and I/O fabrics A common management infrastructure

BladeCenter Blades BladeCenter JS12 BladeCenter JS22

BladeCenter Blades Blades JS12 JS22 i supports the 2-core BladeCenter JS12 and the 4-core BladeCenter JS22 Blades JS12 JS22 Processor Technology POWER6 # of Cores 2 4 GHz 3.8 GHz 4.0 GHz Memory (Min/Max) 2/64 GB 2/32 GB Local Disk (Min/Max) 0/2 73/146 GB 0/1 73/146 GB Base Ethernet Ports (1 GB) Expansion Cards 0-2 Virtualization VIOS/IVM # of Partitions (max) 20 40 AIX Yes Linux i Release 6.1 Processor Tier P05 P10 CPW 7100* 13,800* * Measurements based on an unconstrained environment. Actual performance may be limited by number of disk drives supported

IBM i Support for BladeCenter H Reduce IT costs and complexity by consolidating i and x86 servers with an IBM BladeCenter H solution Enables mid-sized i clients to consolidate their IT environment IBM BladeCenter H supports a combination of 14 POWER6 and x86 blades Delivers the performance required for i applications IBM BladeCenter JS12 delivers 2-core, 3.8 GHz POWER6 performance IBM BladeCenter JS22 delivers 4-core, 4.0 GHz POWER6 performance Supports consolidation of i and x86 storage IBM System Storage DS3200, DS3400, DS4700/4800 and DS8000 PowerVM VIOS partition manages Blade resources AIX and Linux partitions also supported

IBM i Support for BladeCenter S Reduce IT costs and complexity by consolidating System i™ and x86 servers with an IBM BladeCenter S solution Enables small and mid-sized i clients to consolidate their IT environment IBM BladeCenter S supports combination of six POWER6 and x86 blades Delivers the performance required for i applications IBM BladeCenter JS12 delivers 2-core, 3.8 GHz POWER6 performance IBM BladeCenter JS22 delivers 4-core, 4.0 GHz POWER6 performance Supports consolidation of i and x86 storage BladeCenter S offers up to 12 - 450 GB disk drives in the chassis DS3200 provides additional storage PowerVM™ VIOS partition manages Blade resources AIX and Linux partitions also supported

Har POWER BladeServer de kendte fordele?

Virtualization with PowerVM PowerVM VIOS owns resources and storage devices and IVM is used to set up and manage partitions for i on the BladeCenter PowerVM VIOS Based Virtualization i partition uses I/O resources from a VIOS partition VIOS also provides virtualization for AIX and Linux partitions Included with PowerVM Editions Requires POWER6 processor-based systems and i 6.1 Supports DS3200, DS3400, DS4700, DS4800, DS8100 and DS8300 VIOS i Hypervisor JS12 / JS22 Integrated Virtualization Manager Tool that runs in VIOS partition for creating and managing partitions Provides an alternative to HMC for LPAR management Requires VIOS to own i I/O resources Included with PowerVM Editions Supported on BladeCenter JS12 and JS22 with i 6.1

BladeCenter H Configuration with i Partitioned Blade Examples BladeCenter H Chassis Fibre, Ethernet, SAS Switch(s) DVD JS12 Blade 2 Cores, up to 64 GB of Memory 1 or 2 Disk Drives Fibre, Ethernet, SAS Adapters JS22 Blade 4 Cores, up to 32 GB of Memory 1 Disk Drive Storage DS3200,DS3400, DS4700, DS4800, DS8100, or DS8300 External SAS Tape Drive VIOS partition manages Blade resources IVM is used to set up and manage partitions i, AIX, and Linux are client partitions i 6.1 Processor and User entitlements VIOS i Hypervisor JS12 / JS22 VIOS i i Hypervisor JS12 /JS22 VIOS i AIX Linux Hypervisor JS12 / JS22

BladeCenter S Configuration with i BladeCenter S Chassis SAS, Ethernet Switch(s) Up to 12 SAS Drives (450 GB each maximum) DVD JS12 Blade 2 Cores, up to 64 GB of Memory 1 or 2 Disk Drives SAS, Ethernet Adapters JS22 Blade 4 Cores, up to 32 GB of Memory 1 Disk Drive Ethernet, SAS Adapters Storage External SAS Tape Drive DS3200 VIOS partition manages Blade resources IVM is used to set up and manage partitions i, AIX, and Linux are client partitions i 6.1 Processor and User entitlements Partitioned Blade Examples VIOS i Hypervisor JS12 / JS22 VIOS i i Hypervisor JS12 / JS22 VIOS i AIX Linux Hypervisor JS12 / JS22

DS3200 Enhances BladeCenter S with IBM i Provides additional SAS-based storage capacity for BladeCenter S and H configurations 3.6 TB of storage capacity with 12 300 GB SAS disks in the first enclosure, Expandable to a total of 48 disks and 14.4 TB storage capacity with 300 GB SAS disk drives by attaching 3 additional EXP3000 enclosures Using SATA drives, the DS3200 supports up to 48TB of disk Supports 73 GB, 146 GB, and 300 GB SAS drives and 500 GB and 1 TB SATA drives with RAID 0,1, 3, 5, and 10 Supported through VIOS with SAS Expansion Card for BladeCenter (#8250) for BladeCenter JS12 and JS22 BladeCenter SAS Connectivity Module (#3267) for BladeCenter S and H chassis Two SAS Connectivity Modules offer redundant paths to the DS3200 Enables consolidation of larger IBM i and x86 environments with BladeCenter S

Compare and Contrast BladeCenter H BladeCenter S There is a choice of two BladeCenter chassis for i deployment BladeCenter H BladeCenter S Up to 14 blades Supports JS12 and JS22 for i Supports x86 blades Requires SAN For a data center Up to six blades Supports JS12 and JS22 for i Supports x86 blades Disk in chassis + DS3200 For office or data center

IBM i Support for Virtual Tape* Virtual tape support enables IBM i partitions to directly backup to PowerVM VIOS attached tape drive saving hardware costs and management time Simplifies backup and restore processing with BladeCenter implementations IBM i 6.1 partitions on BladeCenter JS12 & JS22 Supports IBM i save/restore commands & BRMS Best solution for BladeCenter S implementations Simplifies migration to blades from tower/rack servers LTO-4 drive can read backup tapes from LTO-2, 3, 4 drives Can also be used with VIOS and IBM i on POWER6 processor-based servers Supports IBM Systems Storage SAS LTO-4 Drive TS2240 for BladeCenter and Power Servers FC #5746, #1404, and #5720 for Power Servers *) All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.

Opsummering IBM Bladeservere er billige i strøm (Grøn-IT), samt enkelt administration. Med IBM Bladeserver samles data på et SAN-system. Der skal kun udvides et sted. HOT spare funktioner / HA løsning Alt i en BOX IBM POWER Blade servere, skal have dedikeret disk-arme tilsluttet fra SAN’et. (XIV) IBM POWER Bladeserver er et ”server” produkt. Hardware service på POWER Bladeserver udføres af IBM’s server specialister, ikke System i teknikere. M3 er testet på POWER Blade og fungere tilfredsstillende, vi har dog ikke endnu en endelig sizing guideline. Vi ved at DISK-SAN (antal diske, samt SAN type) er en vigtig parameter.